Specification for Welded End Cap Model
Series CC Calibration Columns shall be constructed of non-yellowing UV-Resistant PVC with no metal components and provide a sixty second test period for superior dosing accuracy. Direct readings shall be provided in GPH and mL/minute, via high contrast, high visibility graduations provided with clear overlay to resist shrinkage and temperature damage. Cylinder volume shall be [100 mL or 250 mL with ½, 500 mL or 1000 mL with Ύ, 2000 mL or 4000 mL with 1, 10000 mL with 2] [NPT, BSP, Sch 80 Socket, Flange] connections; pressure rating to 75 PSI [change to 40 PSI for 10000 mL with 2 connections]. [add isolation valve option here; see below] All units are to be 100% individually tested at the factory. As manufactured by Plast-O-Matic Valves, Inc., Cedar Grove, NJ USA.
Specification for Removable End Cap Model
Series CC-RE Calibration Columns shall be constructed of non-yellowing UV-Resistant PVC with no metal components and provide a sixty second test period for superior dosing accuracy. Direct readings shall be provided in GPH and mL/minute, via high contrast, high visibility graduations provided with clear overlay to resist shrinkage and temperature damage. Cylinder volume shall be [100 mL or 250 mL with ½, 500 mL or 1000 mL with Ύ, 2000 mL or 4000 mL with 1, 10000 mL with 2] [NPT, BSP, Sch 80 Socket, Flange] connections, with removable end cap and rated for atmospheric pressure. [add isolation valve option here; see below] All units are to be 100% individually tested at the factory. As manufactured by Plast-O-Matic Valves, Inc., Cedar Grove, NJ USA.
Adder for Optional Isolation Valve(s):
Insert: With welded isolation manual ball valve at base. or With welded isolation manual ball valve at base and top.